HLK-75MQ110S24A-1(1)


Input Characteristic

Project Working conditionMin.Typ.Max.Unit

Maximum input current

43 V input voltage, full- load output----2.5A
No-load input current

Rated input voltage

----20mA
Input surge voltage (1sec. max.)

Input values outside this range may cause permanent damage.

-0.7--185VDC
Start-up voltage
----43
Input Undervoltage ProtectionNo-load testing, 

Full-load testing will trigger overcurrent protection prematurely

----42

Remote-controlled foot(CNT)

Positive logic: The CNT pin is left floating or connected to 3.5–15 V to power on;

connect it to 0–1.2 V to power off.




Reference Voltage -

VIN

Negative logic: If the CNT pin is left floating or connected to 3.5–15 V, the device

powers off; if connected to 0–1.2 V, the device powers on.





Output Characteristic

Project Working conditionMin.Typ.Max.Unit

Output voltage regulation accuracy

Nominal input voltage,  from 10%  load--±0.2±1.0%
Linear adjustment rate

At full load, the input voltage ranges from low  to high 

--±0.1±0.2

Load regulation

Nominal input voltage,  from 10% to 100% load

--±0.1±0.5
Transient Recovery Time25% load step change (step rate : 1A/50us)--200250uS
Transient response deviation-5--5
%
Temperature  coefficientFully loaded-0.02--+0.02%/℃
Ripple&Noise

20 MHz bandwidth, tested with an external capacitor of 470 uF or higher

--150240mVp-p
Adjustable output voltage (TRIM)
-20--+10%
Remote compensation of Output Voltage (Sense)
----105%
Over-Temperature ProtectionMaximum surface temperature of the product's metal substrate105115125℃
Output overvoltage protection
125--140%
Output overcurrent protection3.3--4A
Output Short-Circuit ProtectionIntermittent,sustainable,self-recovering


General Characteristic

Project Working conditionMin.Typ.Max.Unit
Isolation VoltageInput-outputTest time 1 min, leakage current <3mA----3000
VAC
Input - HousingTest time 1 min, leakage current<3mA----2100VAC
Output - HousingTest time 1 min, leakage current<3mA----500VDC
Insulation resistanceInput-outputInsulation voltage 500VDC100----MΩ
Switching frequency
--140--KHz
Mean time between failures150----K hours