VRB0505S-6WR3,VRB1205S-6WR3,VRB2405S-6WR3,VRB4805S-6WR3 DC-DC 5V/12V/24V/48V to 5V/12V//15V24V isolated power module
-
Visitor4429
-
Buycount:
-
Price$2.74
Download files:
DC to DC power module:
1W: https://drive.google.com/drive/folders/1vk6luTBKSC5gfwLJC-DbyEZYVDwk87JV
2W: https://drive.google.com/drive/folders/1vjf-77LCVQl16Hcb1phADiU3Hz14mhYB
3W: https://drive.google.com/drive/folders/13pTx02uL4moskJ-PQsBYFytdq2pPt2mN
5W: https://drive.google.com/drive/folders/1okF0YdP1Xs35HxnAkTm45WOK0kH7qlb5?
6W: https://drive.google.com/drive/folders/18IOw7PyIx99lbm3u0FEhkepC82w601sw
10W: https://drive.google.com/drive/folders/1vuJp5ZoJA9Ci0M4wCS8nT689LVzgh2tC
12W: https://drive.google.com/drive/folders/1becUdxQODQ25_A_iarNnun3Vmi_wow1g
20W: https://drive.google.com/drive/folders/182aHyvoN8J0fCurg65jOkfQp17dyaXP6
30W: https://drive.google.com/drive/folders/1StP-0SJDyFpH3yQMLLQjkQXMDXc-RGeP
40W: https://drive.google.com/drive/folders/1IXRm7dueYYTNoyXCFp88wRQexmKAgCLm
B0505S-1WR2: https://drive.google.com/file/d/16BPrOWkzOz7efnf3OvF1XjClKGnO6znv/view
AC to DC power module:
40W: https://drive.google.com/drive/folders/1jI-hITgxjtByhSCpUMmrJATHO8b_gpN7
30W(C): https://drive.google.com/drive/folders/1Nz-_SdQAuVha0JM7nJTelIfophZsmUYb
20W: https://drive.google.com/drive/folders/1PlLOzt_k3Ky5THYGOWP72jqxWSkJsU6Z
15W(C): https://drive.google.com/drive/folders/1vnVfcgQH-OvujpO6asvQvjIgmwUS2Pti
10W: https://drive.google.com/drive/folders/1zaMfq4Dm3brmRWhTGp9-49c8hN5HsIuk
5W: https://drive.google.com/drive/folders/1_dzDfHi9HOnj_b0RJHCGZ9j87ma8PU7g
3W: https://drive.google.com/drive/folders/1xz8MPw9KeQXDlyAQoI3KXzjCoL4yBRVP
2W: https://drive.google.com/file/d/1_UaUPWX9K5Bfavle4C1imVY0-WjY4yso/view
Product Feature
1. Wide input voltage range 2:1, isolated regulated output 6W
2. Isolation voltage 1500VDC
3. Transfer efficiency up to 84%
4. Low ripple noise
5. Operating temperature range :-40°C~+85°C
6. Small SIP package, metal case, low output ripple
7. No-load power consumption less than 0.12W
8. Output short-circuit protection: continuous short circuit protection, automatic recovery
Enviroment Condition
Project name | Qualification | Unit | Notes |
Working enviroment temperature | -40—+85 | ℃ | |
Storage temperture | -40—+125 ℃ | ℃ | |
Relative humidity | 5—95 | % | |
Heat dissipation mode | natural cooling | ||
Atmospheric pressure | 80—106 Kpa | Kpa | |
Ripple & Noise | 50/130(max) | Mvp-p |
Input Characteristics
Item | Working conditions | Min. | Typ. | Max. | Unit | |
Input voltage range(fully loaded/unloaded) | 12VDC Input Series | 3.3V output | - | 476/5 | 490/12 | mA |
5V output | - | 610/5 | 626/12 | |||
others | - | 602/5 | 620/12 | |||
24VDC Input Series | 3.3V output | - | 238/5 | 245/12 | ||
5V output | - | 305/5 | 313/12 | |||
others | 301/5 | 310/12 | ||||
Reflected Ripple Current | - | -- | 50 | -- | mA | |
Impulse voltage (Isec.max) | 12VDC Input Series | -0.7 | -- | 25 | VDC | |
24VDC Input Series | -0.7 | -- | 50 | |||
Start voltage | 12VDC nominal input series, nominal input voltage | - | - | 9 | ||
24VDC nominal input series, nominal input voltage | - | - | 18 | |||
Input undervoltage protection | 12VDC nominal input series, nominal input voltage | 5.5 | 7.0 | - | ||
24VDC nominal input series, nominal input voltage | 13 | 16.0 | - | |||
Input filter type | Capacitance filter type | |||||
Hot plugged | Non-support |
Output Characteristics
Project name | Working and testing condition | Min. | Typ. | Max. | Unit | |
Output voltage accuracy | 5%~100% no-load, input voltage range | 3.3V/5V output | -- | ±3.0 | ±5.0 | % |
others | -- | ±1.0 | ±2.0 | % | ||
Line Regulation | Full load, input voltage changes from low voltage to high voltage | -- | ±0.5 | ±1.0 | % | |
Load Regulation | 5%~100% load | -- | ±0.5 | ±1.5 | % | |
Transient Recovery Time | 25% load step change | -- | ±5 | ±8 | mS | |
Transient response bias | -- | ±3 | ±5 | % | ||
Ripple&Noise | Pure resistive load, 20MHz bandwidth, peak to peak value | -- | 50 | 130 | mVp-p | |
Temperature drift coefficient | full load | -- | ±0.02 | ±0.03 | %/°C | |
Short Circuit Protection | Sustainable, self-healing | |||||
Note:The testing method for ripple and noise is the twisted pair testing method. |
Note:
1、The above is only a list of typical products. If you need products beyond the list, please contact our sales. 2、The maximum capacitive load indicates the maximum capacitive load that + VO or - vo can be connected to,If the value is exceeded, the product will not start normally..
Typical Application Circuits
EMC parameter recommendation
Component No. | Function | Recommended value |
FMSE | Slow blowing fuse, selected according to the actual input current of the customer | |
CY1 safety capacitor | 1nF/250Vac |